STOP
CONTRAST+
CONTRAST-
RETURN
1: 0 m/min
TRIGGER SETUP
PRESSURE SIGNALING
PRESSURE ASSIGNMENT
PRESSURE CURVE
SPIKE VOLTAGE
SPIKE DURATION
SHUTTER ASSIGNMENT
SHUTTER DWELL TIME
CHANGE SECURITY LOCK
1
2
3
4
5
6
7
8
9
Code
--
--
--
--
--
--
--
--
SERVICE SETTINGS 2 OF 3
123
2: 0 m/min
3: 0 m/min
4: 0 m/min
Page 4-- 8
Manual #50-14 Revised 8/08
C. 1998
Service Settin gs Menu 2 (of 3) Overview
1 Trigger Setup: Use this menu to select the
properties of the trigger devices used.That
means the NPN--PNP selection.
2 Pressure Signaling: Use t his menu to configure
the pressure control outputs. You can select from
0--10VDC/ 0--20 mA or 4--20 mA.
3 Pressure Assignment: Use this menu to assign each of the pressure control
outputs to one of the encoders.
4 Pressure Curve: Use this menu to select between 2 or 12 point pressure curve.
5 Spike Voltage: You can select the overexcitation voltage 55V or 170V for each
channel, or you can deactivate the overexcitation for this channel.
6 Spike Duration: The duration time of the overexcitation is programmable between
0.5ms and 2.5ms.
7 Shutter Assignment: Use this menu to assign the shutter output (X23) to one of
the triggers.
8 Shutter Dwell Time: Use this menu to adjust the duration of time the shutter circuit
remains active after the last trigger input. Values range from 1 to 99 seconds.
9 Change Security Lock: This menu is used to lock individual functions to prevent
unauthorized modification. Additionally it is possible to change the access code. You
can lock/unlock every above mentioned function. After locking, these functions are
only available via access code. Locking/Unlocking is only possible if you know the
access code.