EasyManua.ls Logo

ITW Dynatec DY 2008 - Service Settings Menu 2 of 3 Overview

Default Icon
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STOP
CONTRAST+
CONTRAST-
RETURN
1: 0 m/min
TRIGGER SETUP
PRESSURE SIGNALING
PRESSURE ASSIGNMENT
PRESSURE CURVE
SPIKE VOLTAGE
SPIKE DURATION
SHUTTER ASSIGNMENT
SHUTTER DWELL TIME
CHANGE SECURITY LOCK
1
2
3
4
5
6
7
8
9
Code
--
--
--
--
--
--
--
--
SERVICE SETTINGS 2 OF 3
123
2: 0 m/min
3: 0 m/min
4: 0 m/min
Page 4-- 8
Manual #50-14 Revised 8/08
C. 1998
Service Settin gs Menu 2 (of 3) Overview
1 Trigger Setup: Use this menu to select the
properties of the trigger devices used.That
means the NPN--PNP selection.
2 Pressure Signaling: Use t his menu to configure
the pressure control outputs. You can select from
0--10VDC/ 0--20 mA or 4--20 mA.
3 Pressure Assignment: Use this menu to assign each of the pressure control
outputs to one of the encoders.
4 Pressure Curve: Use this menu to select between 2 or 12 point pressure curve.
5 Spike Voltage: You can select the overexcitation voltage 55V or 170V for each
channel, or you can deactivate the overexcitation for this channel.
6 Spike Duration: The duration time of the overexcitation is programmable between
0.5ms and 2.5ms.
7 Shutter Assignment: Use this menu to assign the shutter output (X23) to one of
the triggers.
8 Shutter Dwell Time: Use this menu to adjust the duration of time the shutter circuit
remains active after the last trigger input. Values range from 1 to 99 seconds.
9 Change Security Lock: This menu is used to lock individual functions to prevent
unauthorized modification. Additionally it is possible to change the access code. You
can lock/unlock every above mentioned function. After locking, these functions are
only available via access code. Locking/Unlocking is only possible if you know the
access code.