Spike Duration Adjustment
This menu allows selection of the duration for the
“SPIKE VOLTAGE” programmed in the previous
section.
Press button 6.
Enter Access Code if this function is
protected.
Press Enter Button.
Note! Time values range from 0.50 to 2.50ms;
1.60ms ( default) is recommented for most
applications.
Use button F1 or F2 to select a channel.
PressbuttonF3toswitchtothespiketime
field.
Press button F1 to increase the spike
duration time by a step of 0.05 ms.
Press button F2 to decrease the spike
duration time by a step of 0.05 ms.
or
Use the numeric buttons to enter the
desired value.
Press the Enter button and repeat the
procedure for addtional channels.
Press F4 to return to previous menu.
STOP1: 0 m/min
2: 0 m/min
3: 0 m/min
SPIKE DURATION MENU
TIME
CHAN.
1
2
3
4
4: 0 m/min
RETURN
1.60 ms
1.60 ms
1.60 ms
1.60 ms
STOP1: 0 m/min
2: 0 m/min
3: 0 m/min
SPIKE DURATION TIME
TIME
CHAN.
1
2
3
4
4: 0 m/min
RETURN
.90 ms
1.60 ms
1.60 ms
1.60 ms
+0.05 ms
-0.05 ms
123
.90 ms