RETURN
ACCESS CODE: ----
STOP
1: 0 m/min
2: 0 m/min
3: 0 m/min
4: 0 m/min
RETURN
STOP
CONTRAST+
CONTRAST-
RETURN
1: 0 m/min
TRIGGER SETUP
PRESSURE SIGNALING
PRESSURE ASSIGNMENT
PRESSURE CURVE
SPIKE VOLTAGE
SPIKE DURATION
SHUTTER ASSIGNMENT
SHUTTER DWELL TIME
CHANGE SECURITY LOCK
1
2
3
4
5
6
7
8
9
Code
--
--
--
--
--
--
--
--
SERVICE SETTINGS 2 OF 3
123
2: 0 m/min
3: 0 m/min
4: 0 m/min
Manual #50-14 Revised 8/08
Page 4-- 27
C. 1998
Spike Voltage Adjustment
Caution!
The factory default overexcitation voltage for applicator heads is “off”. Make
sure this setting is appropriate for the equipment used in your system. If
necessary change this value.
Note! ITW Dynatec DynaCold Series applicators must always be operated with
170V spike voltage.
Press button 5.
Enter Access Code if this function is
protected.
Press Enter Button.
Use button F1 or F2 to select a channel.
Press button F3 to choose t he spike voltage
of “55V”, “170V” or “OFF”.
Press Enter button and repeat the
procedure for additional channels.
Press F4 to return to previous menu.
STOP1: 0 m/min
2: 0 m/min
3: 0 m/min
SPIKE VOLTAGE MENU
SPIKE VOLTAGE
CHAN.
1
2
3
4
4: 0 m/min
RETURN
55V
55V
55V
55V
STOP1: 0 m/min
2: 0 m/min
3: 0 m/min
SPIKE VOLTAGE MENU
SPIKE VOLTAGE
CHAN.
1
2
3
4
4: 0 m/min
RETURN
170V
55V
55V
55V
1