RETURN
1: 0 m/min
2: 0 m/min
3: 0 m/min
4: 0 m/min
STOP-CONFIGURATION
PC-COMMUNICATION
RESERVE
SHUTTER
RESERVE
DIGITAL
RESERVE
LOAD FACTORY SETUP
CHANGE SECURITY LOCK
1
2
3
4
5
6
7
8
9
Code
--
--
--
--
--
--
--
SERVICE SETTINGS 3 OF 3
Manual #50-14 Revised 8/08
Page 4-- 9
C. 1998
Service Settin gs Menu 3 (of 3) Overview
1 STOP--Configuration: Use this menu to select
the Stop Mode for each channel: Complete or do
not complete an interrupted gluing pattern upon
machine restart.
2 PC--Communication: Use this menu to select
RS232 or RS485 data protocol and to adjust the
baud rate.
3 Reserve: This menu is not used.
4 Shutter Trigger Setup: Use this menu to select a NPN or PNP shutter trigger
device.
5 Reserve: This menu is not used.
6 Digital Configuration: Use this menu to configure the Machine Contact (X19) and
Alarm Output (X21).
7 Reserve: This menu is not used.
8 Load Factory Setup: In this menu you can reload the factory default for the active
program. After entering the access code the active program will be reset to the
values listed below.
9 Change Security Lock: This menu is used to lock individual functions to prevent
unauthorized modification. Additionally it is possible to change the access code. You
can lock/unlock every above mentioned function. After locking, these functions are
only available via access code. Locking/Unlocking is only possible if you know the
access code.
Factory Default Values
Service Settings Menu 1 of 3
No
.
Function Setting
1 Language English
2 Program As per operator selection
3 Trigger Assignment All Channels are assigned to Trigger 1.
The ’AND’--function is deactivated
4 Trigger Lock All Channels set to 1 mm ( 0.01 in)
5 Encoder Assignment All Channels are assigned to Encoder 1.
6 Encoder Scaling All Encoders are scaled to 1000 pulses/meter (10.00 ppi)
7 Speed Configuration All Encoders:
Gluing starts above 20 m/min (20 ft.min)
Gluing stops below 30 m/min (30 ft/min)
Maximum Machine Speed: 600 m/min (600 ft/min)
8 Channel--Mode All Channels are set to “Standard”
9 Security Lock Access code 1111, this function locked
All previous functions are unlocked