Page 4-- 10
Manual #50-14 Revised 8/08
C. 1998
Service Settings Menu 2 of 3
No
.
Function Setting
1 Trigger Setup All Triggers set to NPN
2 Pressure Signaling All Pressure outputs set to 4--20 mA
3 Pressure Assignment All Pressure outputs assigned to Encoder 1
4 Pressure Curve All Outputs set to 2--Point curve
5 Spike Voltage All Channels set to 55 V
6 Spike Duration All Channels set to 1.6 ms
7 Shutter Assignment The Shutter output (X23) is assigned to the shutter trigger
(X20)
8 Shutter Dwell Time 2sec.
9 Security Lock Accesscode 1111, this function locked
All previous functions are unlocked
Service Settings Menu 3 of 3
No
.
Function Setting
1 STOP--Configuration All Channels: “NOT FINISH GLUING UPON RESTART”
2 PC--Communication As previously programmed
3 Reserve not used, Function locked
4 Shutter Trigger Setting NPN
5 Reserve not used, Function locked
6 Digital Configuration Machine Contact: Normally Open
Relay 1: Stop Relay 2: Alarm
7 Reserve not used, Function locked
8 Load Factory Default Function Locked
9 Security Lock Access code 1111, this function locked
All previous functions are unlocked
Production Menus
Function Setting
Pattern All Channels: Del.1 = 10mm (0.10 in), Glue 1 = 20 mm (0.20 in)
Pressure All Outputs: Min: 0%, Max: 100%, Purge: 70%
Stitch All Channels: Glue 4mm (0.04 in), Gap 4mm (0.04 in), no stitch
functions are active
Offset All Channels: 20mm (0.20 in)
Compensation All Channels: ON: 0, OFF: 0