Pressure Adjustment
The shown display appears a few seconds after
switching on the pattern controller. If you are in a
different menu, press F4 RETURN as many times as
necessary to return to the Main Menu, as shown at
right.
Press button F2.
Use button F3 to select a Pressure Output.
Note! Depending on whether a 2--Point or
12--Point Pressure Curve is selected for
the particular pressure output (X24 thru
27) (Service Setting Menu 2 of 3, Function
4) different settings are necessary.
Minimum Pressure Adju stment (2-Point Curve)
Use the numeric keys to enter the minimum
pressure at zero machine speed, e.g. 10%.
Maximum Pressure Adjustment (2-Point Curve)
Press button F1 or F2 to select the pressure
at maximum machine speed.
Use the numeric keys to enter the pressure
for maximum machine speed e.g. 90%.