EasyManua.ls Logo

ITW Dynatec DY 2008 - Manual Gluing (Purge)

Default Icon
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RETURN
C1:
C2:
C3:
C4:
C5:
C6:
C7:
C8:
PATTERN
PRESSURE
SYSTEM COMP.
1: 0 m/min
PRESS1: 0%
PRESS2: 0%
PRESS3: 0%
PRESS4: 0% PROGRAM.:
1
2: 0 m/min
3: 0 m/min
4: 0 m/min
CHAN. 1:
CHAN. 2:
CHAN. 3:
CHAN. 4:
RETURN
OFF
OFF
OFF
OFF
1: 0 m/min
STOP
MANUAL GLUING
CHAN. 1
ON
Manual #50-14 Revised 8/08
Page 4-- 55
C. 1998
Select another channel using the button F1
and F2 and repeat the procedure for all
channels in the same way.
Press F4 to return to previous menu.
Manual Gluing (Purge)
Manual Gluing provides a means to activate any or all glue applicators f or maintenance
functions. It can only be performed when the DY2008 is in a stop” condition, as indicated
by STOP or COM2-STOP flashing at the top, center portion of the display panel (see “Stop
Function” in this chapter).
The DY2008 automatically adjusts its pressure outputs (X24 through X27) to the
programmed PURGE PRESSURE (see “Pressure Adjustment” in this chapter) upon
entering the Manual Gluing menu. The PURGE PRESSURE outputs will remain active until
the MANUAL GLUING menu is exited, at which time the output pressures revert back to
levels as programmed in the 2-Point or 12-Point pressure menus.
Manual Gluing may be accomplished from either the front panel of the DY2008 or via the
optional Remote Purge Control (28.11101.602), if installed.
MANUAL GLUING VIA THE DY2008 FRONT PANEL
Press the STOP button at the top, right
corner of the DY2008 front panel keypad
until STOP is flashing on the front panel
display
Press the MANUAL GLUING button at the
top, left corner of the DY2008 front panel
keypad to display t he MANUAL GLUING
menu.
Use the F1 or F2 buttons to select the
channel to be activated for manual gluing.
Press and hold theF3buttontoactivatethe
selected channel.