RETURN
CHAN.
11
2
3
4
MODE
STANDARD
STANDARD with dot
DOT
STANDARD
STOP
1: 0 m/min
2: 0 m/min
3: 0 m/min
4: 0 m/min
CHANNEL MODEE MENU
RANDOM LENGTH
4
TIME
TIME
2
RETURN
CHAN.
1
TIME
STOP
1: 0 m/min
2: 0 m/min
3: 0 m/min
4: 0 m/min
TIME OUT MENU
2 sec.4
RETURN
Manual #50-14 Revised 8/08
Page 4-- 21
C. 1998
Note! Random Length Mode incorporates a “time out”
function to prevent excessive, undesired glue flow in
the event of a product jam under the triggering device.
Set this value to be slightly greater than the longest
anticipated time by taking into account the longest
product and slowest production speeds.
Press F1 to enter the Time Out Menu.
Use the F3 button to select the existing time
value.
Enter the desired time out value via the
numeric keypad.
Press the Enter Button.
Press F4 to return to the previous menu.