5
or
+1mm
4
or
+0.10ms
RETURN
RETURN
RETURN
Manual #50-14 Revised 8/08
Page 4-- 49
C. 1998
Use the numeric keypad or the F1/F2
buttons to enter the desired value for
REPEAT. The F1/F2 buttons will
increment/decrement the REPEAT value in
1mm (0.01”) steps as a fine-tuning
adjustment capability.
Press the F3 button to highlight the GLUE
value. THe GLUE value is the time in
milliseconds that the glue applicator will be
turned on to produced the dot.
Use the numeric keypad or the F1/F2
buttons to enter the desired value for GLUE.
The F1/F2 buttons will
increment/decrement the GLUE value in
0.10 millisecond steps as a fine-tuning
adjustment capability.
Press the F4 button, then select the next
channel.
Repeat the above procedures for each
channel.
Press the F4 button to return to the System
Menu.
Press the F4 button to return to the Main
Menu.
CHAN. 2
CHAN. 3
1: 0 m/min
STOP
ZURUECK
DOT CONFIGURATION REPEAT (mm) GLUE (ms)
RETURN
5
10
1.00
4.50
4.00
+ 0.10 ms - 0.10 ms
123