4
07610-003-60-98-L
SPECIFICATIONS
MACHINE DIMENSIONS
AJX-54 LEFT-TO-RIGHT
Front
Top
75
1
2
[1915 mm]
62
1
2
[1588 mm]
29 [737 mm]
10 [254 mm]
7 [178 mm]
4 [102 mm]
8 [203 mm]
Table-to-Table
Overall
54 [1372 mm]
62 [1575 mm]
72 [1829 mm]
14 [355 mm]
MIN
21 [535 mm]
Machine
Drain Line
1 1/2 [38 mm]
MIN, Must NOT
Be Reduced.
Pitch 1/4 [6 mm]
per ft.
Must Install Machine
Drain Line above
3 [76 mm] MIN
Floor Drain or Sink
1 1/2
[38 mm]
MIN
Air-gap
A
B
D
E
A
B
4 [102 mm]
MIN
LEGEND
A - Main Water Inlet
(3/4" NPT, 180 °F MIN)
B - Electrical Connection
C - Drain Connection (1 1/2" NPT)
D - Vent Collar - Optional
E - Vent Cowl - Standard
F - Machine Steam Inlet (3/4" NPT)
G - Condensate Return (3/4" NPT)
H - Steam Booster Electrical Connection (7/8" Hole)
J - Booster Steam Inlet (1" NPT)
K - Condensate Connection (3/4" NPT)
L - Water Inlet for Booster (from Facility)
(3/4" NPT, 110 °F)
M - Water Outlet to Machine
(3/4" NPT, 180 °F)
All dimensions from the floor can be
increased 1” using the machine’s
adjustable feet.
Items in red are not supplied
with the machine.
Items in blue are for the Steam option.
Scrap Trough
7 [178 mm]
DRIVE KEY
STROKE
34 [864 mm]
8
1
2
[218 mm]
21 [533 mm]
25 [635 mm]
12 [307 mm]
25 [635 mm]
1
2
[15 mm]
84 [2134 mm]
CLEARANCE
Left Right
66 [1692 mm]
1 [25 mm]
65 [1665 mm]
25 [635 mm]
A
B
C
M
J
K
H
33
1
8
[841 mm]
20
3
4
[527 mm]
14
5
8
[372 mm]
2
7
8
[76 mm]
20
1
8
[511 mm]
22 [559 mm]
3
3
8
[86 mm]
11
3
8
[289 mm]
J
L
M
33
11
16
[856 mm]
20
1
4
[514 mm]
Front
Top
Steam Booster
DOOR OPEN
23 [597 mm]
DRIVE
UNIT
DRIVE
UNIT
1
2
11 [289 mm]
3
8
11 [283 mm]
6 [165 mm]
C
G
1
2
7 [191 mm]
1
2
1
8
9 [238 mm]
3
8
1
2
1
2
60
1
4
[1528 mm]
F
17 [442 mm]
1
2
4 [102 mm] x 16 [406 mm]
Cut-out in Vent Cowl/Splash Shield.
Shipped with Cover Plate.
8 [203 mm]
F
12
1
2
[316 mm]