36
07610-003-60-98-L
TROUBLESHOOTING
TROUBLESHOOTING
OBSERVATION POSSIBLE CAUSE REMEDY
Nothing on machine
operates. The power
switch is ON and the
power indicator light is
OFF.
1. Machine is not wired correctly
to incoming power source.
2. Machine circuit breaker is
tripped.
3. Service breaker is tripped.
1. Have an electrician verify wiring.
2. Reset the circuit breaker. If it trips again, contact an
electrician to verify the machine amp draw.
3. Reset the service breaker. If it trips again, contact an
electrician to verify the machine amp draw.
Machine will not ll. The
power switch is ON and
the power indicator light
is ON.
1. No water supplied to machine.
2. Machine doors are not
closed.
3. Incoming water solenoid valve
damaged/faulty.
4. Tank oats faulty.
1. Verify water lines have been connected to the machine.
2. Close doors completely.
3. Verify the valve is operating. If not, replace.
4. Verify the wiring of the oats. Verify that no debris is jamming
the oats. Replace if necessary.
Machine lls, but ll is
weak.
1. Low incoming water pressure.
2. Incoming water solenoid is
clogged.
1. Verify incoming water pressure during ll is 15 PSI.
2. Verify debris is not trapped in valve. If so, remove
debris.
Low wash tank
temperature.
1. Low incoming water
temperature.
2. Heater not energizing.
3. Low incoming voltage.
1. Verify the incoming water temperature matches the data
plate.
2. Verify the wash tank heater is operating. If not, replace.
3. Have an electrician verify incoming power is the same
as indicated on the data plate.
Low wash arm pressure,
poor spray pattern.
1. Clogged wash arm nozzles.
2. Clogged wash tank or wash
pump strainers.
3. Worn wash pump impeller.
1. Verify nozzles are not clogged with debris. If so, remove
debris.
2. Clean out strainers if necessary.
3. Verify status of impeller and replace if necessary.
Inadequate rinse.
1. Low incoming water pressure.
2. Incoming water solenoid is
clogged.
1. Verify incoming water pressure during ll is 15 PSI.
2. Verify debris is not trapped in valve. If so, remove
debris.
WARNING: Inspection, testing, and repair of electrical equipment should only be performed by a
qualied service technician. Many of the tests require that the machine have power to it and live
electrical components be exposed. USE EXTREME CAUTION WHEN TESTING THE MACHINE.
!
WARNING

Table of Contents

Other manuals for Jackson AJX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jackson AJX Series and is the answer not in the manual?

Jackson AJX Series Specifications

General IconGeneral
BrandJackson
ModelAJX Series
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals