EasyManuals Logo

Jandy TruClear User Manual

Jandy TruClear
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Page 7
ENGLISH
Jandy
®
Pro Series TruClear
Chlorine Generating System
|
Installation & Operation Manual
WARNING
To minimize risk of severe injury or death, filter, pump, and/or chlorinator should not be subjected to the piping
system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements are gener-
ally not intended to apply to the pool equipment, such as filters, pumps, or chlorinators.
Jandy pool equipment is pressure tested at the factory.
If, however, the WARNING cannot be followed and pressure testing of the piping system must include the filter,
pump, and/or chlorinator, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings, and system accessories to ensure they are properly installed and se-
cured before testing.
• RELEASE ALL AIR in the system before testing. AIR PRESSURE must NOT be used for pressure testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100°F (38°C)
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Notice: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult the equipment
manufacturer.
SAVE THESE INSTRUCTIONS
WARNING
The power pack must be installed at least 0.6 m (2 ft.) vertically off the ground.
In the US, the power pack must be installed at least 1.5 m (5 ft.) from the inside wall of your swimming pool or
spa; in Canada, the power pack must be installed at least 3 m (10 ft.) from the inside wall of your
swimming pool or spa.
The Jandy Pro Series chlorine generating device must be installed outdoors only. The cell must be installed
horizontally with the cord facing upwards to avoid buildup of flammable gases which can result in FIRE OR
EXPLOSION.
The cell must be installed as the last piece of equipment in the circulation plumbing system just before the pool.
To Reduce the Risk of Fire, install pool equipment in an area where leaves or other debris will not collect on or
around the equipment. Keep surrounding area clear of all debris such as paper, leaves, pine-needles and other
combustible materials.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy TruClear and is the answer not in the manual?

Jandy TruClear Specifications

General IconGeneral
TypeSaltwater Chlorinator
Cell MaterialTitanium
Pool Size CapacityUp to 40, 000 gallons
Control InterfaceDigital
Power Supply120/240 VAC
InstallationInline plumbing installation
Salinity Range2500 - 4500 ppm
Plumbing Size2 inch

Related product manuals