M
Ingenieurbüro CAT, M. Zipperer GmbH +49-7634-5056-800
Wettelbrunner Straße 6 sales@jetcat.de
47 79282 Ballrechten-Dottingen www.jetcat.de
GERMANY
Instruction
m
-
PRO engines
,
1.7
-
V12.01V
23 No-OIL Not applicable for PRO engines
24 OverCurr The electrical current to the engine is too high.
Starter may be jammed
Kero/glow plug is short circuited
25 No Pump! There is either no pump connected, or the pump cable is defective.
26 Wrong Pmp Wrong pump type, see pump configuration in the advanced section of the manual.
27 Pump Err Communication to pump driver disturbed.
28 No Fuel! Not applicable for PRO engines
29
LoRpmPmp
Pump driver
problem
30 LowRpmFB Rpm measurement subsystem error
31 !Clutch Clutch of Starter motor does not disengage
32 EngMatch Not applicable for PRO engines
33 CAN-Error Engine has been started up via CAN-Bus, but then the CAN Bus has been
disconnected (no commands received)
34 NoRcPuls Engine has been started up via THR channel, but then the THR signal has been
disconnected.
35 RotorBlck Rotor of engine is blocked
36 Kill Sig The “Kill signal” was activated, which will turn off the power to the fuel solenoids as
well as disable power to the pump(s) via an independent secondary hardware
circuit.
(See also:
pinout of 15pin SUB
-
D connector)
37 Restart Aborted AutoRestart was triggered and AutoRestart option is set to “MaxThrottle”.
However throttle stick was not set to max throttle position by user within 6sec
timeout
period
e
Restart aborted