Temperature calibration
After a replace of a temperature sensor (EGT sensor) it might be necessary to run a temperature calibration
The engine must be at ambient temperature (approx. 21°C)!
Press and hold the „Select Menu“ key on GSU, then switch on ECU (receiver). Instead of „Select Menu“key of GSU, it’s
possible to press the little key on the LED-board.
The LED´s indicate the following blink sequence:
LED Blink Sequence
Standby (yellow)
Pump running (red)
OK (green)
The display of GSU indicates simultaneously: Release Key to „Learn RC“
While this sequence hold the key „SelectMenu“ don’t release it !!!!
Release the key if the three LED´s indicate this blink sequence:
LED Blink Sequence
Standby (yellow)
Pump running (red)
OK (green)
The display of the GSU indicate simultaneously: “Release Key to Calibrate Temp“
after releasing the key on the GSU the temperature calibration is executed.