EasyManua.ls Logo

JetCat P550-PRO - INFO Menu Data Display

Default Icon
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M
Ingenieurbüro CAT, M. Zipperer GmbH +49-7634-5056-800
Wettelbrunner Straße 6 sales@jetcat.de
54 79282 Ballrechten-Dottingen www.jetcat.de
GERMANY
Instruction
m
-
PRO engines
,
1.7
-
V12.01V
The INFO Menu
Info menu displays the following information:
Value Explanation
Rest Fuel Remaining fuel in tank. Tank size can be entered using the LIMITs menu. Value is reset
every time the ECU is switched on (or can be reset manually by pressing the Change
Value/Item button on the GSU).
Fuel Flow ml/min
Actual fuel con
sumption in ml/min.
BattCnd
Ubattery
The condition of the battery is indicated in the upper line:
1. --OK--
2. !WEAK!
3. --EMPTY--
1. If the battery voltage is 1.1V/Cell or higher “—OK--“ will be displayed.
2. If the battery voltage drops under 1.1V/Cell, the display will read “!WEAK!”. Red
Standby/Manual and green OK LED’s will blink simultaneously (at a rate of twice
per second). Starting the engine is not possible, until the battery is recharged. If the
engine is already running and the battery warning function is enabled, the warning
function will be activated.
3. If the battery voltage drops under 1.0V/Cell “—EMPTY-- is displayed. Starting the
engine is not possible until the battery is recharged. If the engine is running, it will
be immediately shut off, to avoid a malfunction of the ECU.
Current voltage of the battery. Displayed on bottom line.
Baro
Temp
Indicate the current barometric pressure.
Temperature indicator (C°) in range of ECU
Last Run Time Last engine run time.
Last Fuel Count Quantity of fuel consumed, during the last engine run.
Last-Off PmpVolt Volts applied to the pump when it was switched off.
Last Off RPM RPM of the engine, when it was switched off.
Last Off TEMP Temperature of the engine, when it was switched off.
Last Off Cond Last stored Off condition.
Last Max Temp Maximum temperature during the last engine run
Last Min Temp Minimum temperature during the last engine run
Last AVG Temp Average temperature during the last engine run
Last MaxR AVGTmp Average full throttle temperature during the last engine run
Last Max Pump Maximum pump voltage during the last engine run
Last Min Pump Minimum pump voltage during the last engine run
Last Avg Pump Average pump voltage during the last engine run
Last Fail Safe Cnt Number of Fail Safe during the last engine run
Last Fail Safe Time Fail Safe Time in seconds
Last-Max AirSpd Maximum reached flight speed during the last flight
(
Only
by connected
Airspeed sensor
!)

Table of Contents

Related product manuals