SECTION 3 - MACHINE OPERATION
3-16 31215821
Table 3-2. LCD Display - Operating Fault Conditions
FAULT
CODE
PLATFORM
LEDs
FLASHING
LCD SYMBOL SCREEN LCD TEXT SCREEN
FAULT DESCRIPTION/
MACHINE CONDITION
TO CORRECT PROBLEM
— —
Brakes Released -
(DRIVE Disabled)
To Engage Brakes - Press Brake
Release Button on Ground Control
Station
— — —
Charger AC Plugged In DRIVE Dis-
abled
Unplug Charger AC Power Cord
— —
Programmable Security Lock Pass-
word
Enter Code on PSL Keypad to Power-
Up Machine
— 3
Low Battery -
(Warning Level 1)
Charge Batteries to Four (4) Bars or
more on Indicator.
— 2
Charge Battery - (LIFT UP Disabled)
(Warning Level 2)
Charge Batteries a Minimum of Four
(4) Hours or eight (8) LEDs/BARS lit.
— 1
Charge Battery - (LIFT UP/DRIVE Dis-
abled) (Warning Level 3)
Charge Batteries a Minimum of Four
(4) Hours or eight (8) LEDs/BARS lit.
4 3
Tilt Condition (Platform Elevated)
DRIVE and Lift UP Disabled
Lower the Platform and Drive off the
Tilt Condition
00000.0
00000.0