EasyManua.ls Logo

Johnson Controls Frick SGC 1913 - Page 119

Johnson Controls Frick SGC 1913
171 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Engineering manual - SAB 193-233-283 S A-frame (including ATEX)
008831 en 2020.10
119/168
Installation instructions
Reactions: Unit to be seen from top
F1 1376 F3 1302
x = 0,
Y = 1070 = b
x = 3419 = L,
y = 1070
Motor
Compressor
F2
1461
F4
1383
x = 0,
y = 0
x = 3419 =l,
y = 0
Filter Oil cooler
Table 44
Calculation of tipping angle
Tipping angle = atan YK/ZG
where
YK = YG if YG < b/2
or YK = (b - YG) if YG > b/2
Calculated tipping angle
YK = YG = 519
26.1
degrees
Fig. 81
Type
Dimensions in mm Overall
bolt
length
Thread
G
Weight
(kg)
Max.
load
(Kg)
D
H min.
H max.
TF 3000
151
35
1)
120 M 20 2.2 3000
TF 4000 170 39
1)
120 M 20 2.9 4000
TF 6000 205
44
1)
150 M 24 4.8 6000
1) Levelling of the bolt up to its total length
Table 45: List of vibration dampers
Type
Compression Max. load
[kg]
1 1.5
2 2.5
TF3000-80 400 900 1450 2150 3000
TF4000-80 440 1530 2450 4700 4000
TF6000-80 1000 2000 3000 4000 6000
Table 46: Loading range
H
G
D

Table of Contents