Engineering manual - SAB 193-233-283 S A-frame (including ATEX)
008831 en 2020.10
85/168
Physical and connection data
5.4.3 List of components
151 TE1 Suction gas temperature
152 TE2
Discharge gas temperature
153 TE3
Oil temperature
154 TE4
Separator oil temperature
155 PE1
Oil pressure
156 PE2
Oil pressure filter before compressor
157 PE3
Discharge gas pressure
158
PE4 Suction pressure
159 PS
Pressure switch control
160 LSLL
Low level shutdown
161 HTR 1 Heater
163 High level transmitter
ZI2
Capacity linear transmitter, slide valve
ZI3
Volumizer transmitter, slide stop
YY-1
Solenoid valve. Energise unload slide valve
YY-2
Solenoid valve. Energise increase volume rate
YY-3
Solenoid valve. Energise increase volume ratio
YY-4
Solenoid valve. Energise decrease volume ratio
EC
UniSAB III electronic computer control
PM-1 Pump motor
192
Electric motor
Motor, pos. M
Connection data for supply voltage:
VAC
Permissible variation: +10%/-15%
Frequency: 45-65 Hz
Power:
kW
Supply voltage and motor power appear from the order sheet.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls Frick SGC 1913 and is the answer not in the manual?

Johnson Controls Frick SGC 1913 Specifications

General IconGeneral
BrandJohnson Controls
ModelFrick SGC 1913
CategoryAir Compressor
LanguageEnglish

Related product manuals