Reader Power Requirements
iSTAR Ultra Installation and Configuration Guide 2–13
Reader Power Requirements
This section lists the power requirements for the readers.
Software House Readers
Table 2-10 on page 2-13 shows power requirements for Software House readers.
Table 2-10: Software House Reader Power Requirements
Reader Model Numbers Current Draw at 12 VDC
RM with Multi-Technology Reader RM1-4000, RM2-4000
RM1-SE, RM2-SE
300 mA max
RM with Multi-Technology Reader and LCD RM2L-4000, RM2L-SE 300 mA max
RM with mag stripe RM1-MP, RM2-MP 80 mA max
RM with mag stripe and LCD RM2L-MP 180 mA max
RM with mag stripe mullion RM3-MP 80 mA max
RM with Indala proximity RM1-P, RM2-PI 80 mA max
RM with Indala proximity and LCD RM2L-PI 180 mA max
RM with HID proximity RM1-PH, RM2-PH 250 mA max
RM with HID proximity and LCD RM2L-PH 250 mA max
RM with HID proximity mullion RM3-PH 250 mA max
RM with Wiegand RM1-W 80 mA max
Multi-Technology Contactless Reader SWH-4000
a
, SWH-4100
a
SWH-4200
a
, SWH-3000
a
,
SWH-3100
a
125 mA
Multi-Format Proximity Reader SWH-5000
a
, SWH-5100
a
125 mA
Auxiliary Relay Module ARM-1
a
20 mA (relay active)
RM with HID iClass RM1-IC, RM2-IC 100 to 200 mA max
RM with HID iClass and LCD RM2L-IC 100 to 200 mA max
TST-100 Touchscreen Terminal Reader SWH-TST-100
SWH-TST-100-V
300 mA max
Cheetah SE INN-SECHTA-RF,
INN-SECHTA-CT
INN-SECHTA-RFO
INN-SECHTA-CTO
600 mA max
Cheetah INN-CHTA-RF
INN-CHTA-RF-OD
INN-CHTA-CT
INN-CHTA-CT-OD
INN-CHTA-BIO
INN-CHTA-BIO-CT
1000 mA max