www.modelflight.com.au – World’s best source of JR products
4
.
1
2
G
y
ro Sensitivit
y
Ad
j
ustment
(
Function Mode
)
cont.
two pre-determined settings through the use of the flight mode
switch. As different flight modes are selected (Nor
mal, 1, 2,
Hold), the Gyro’
s
sensitivity rate will switch to the pre-determined
compensation rate for each particular flight mode in use.
Gyro Installation/Adjustment
JR NEJ-1
2
0S Gyro
Gyro Sensitivity Adjustment
Manual Gyro Sensitivity Adjustment
1.
Connect the white connector from the NEJ-1
2
0S gain
controller to the AUX 2 channel of the receiver
.
2.
Select the manual gyro sensitivity feature (RUDD D/R will
appear on the XP8
10
3 screen).
3.
Adjust the 0 position under the RA
TE
on the display to 1
00%
and the 1 position to 0% using the + or - keys.
4.
Adjust the gyro sensitivity for positions 0 and 1 on the
NEJ-1
2
0S gain controller
.
5.
Move the Rudder D/R switch from the low position to the
high position with the gyro ON to verify that it is functioning
properly
, and note the “high/low” sensitivity values relative to
the dual rate switch. Refer to the NEJ-1
2
0S gyro instructions for
fur
ther information.
A
utomatic Gyro Sensitivity Adjustment
1.
Connect the white connector from the NEJ-1
2
0S gain
controller to the AUX 2 channel of the receiver
.
2.
Select the Automatic Gyro Sensitivity Adjustment Feature
(“AUTO” will appear on the screen).
3.
Adjust the 0 position under the RA
TE
on the display to 1
00%
and the 1 position to 0% using the + or - keys.
4.
Under Function Mode select the gyro rate (position #1 or
Position #0) that you wish to be active in each flight mode.
5.
T
ur
n
the system ON and move the flight mode switch to its 3
positions with the gyro ON to verify that it is functioning properly
.
Refer to the NEJ-1
2
0S gyro instructions for fur
ther
infor
mation.
A
utomatic G
y
ro Sensitivit
y
Selection
Automatic or Manual
rate selection
(
automatic shown
)
Flight Mode Rate Selection:
NORM: Normal
STNT: Stunt
HOLD: Throttle Hold (when activated)
INVT: Inverted
(
when activated
)
Press the UP and DN keys
simultaneously to enter/exit
the Function Mode
Press the DN and Select key
s
simultaneously to access th
e
Function Mode List Dis
p
la
y
UP
DN
SELECT CH CH CLEAR
To Program Mixing Function
To Revolution/
Acceleration Mixing
function
Press to move
cursor to position
to be ad
j
usted
Press to move
arrow to rate
position 0 or 1
and to select
rate values for
fli
g
ht modes
Press to activate and
select Gyro Sensitivity
type (Manual or Auto)
INH
Manual
Auto
and to increase or
decrease Gyro
Sensitivity value for
NEJ 1000
Note: For NEJ120, set
the 0 position at 100%
d1 tii t0%
Press to inhibit Gyro
Sensitivity when at the
Auto position, or to
set Gyro Sensitivity
values to 0% at the
arrow
p
osition
HELI
86