Maintenance & Inspection 
6-6 
6.3.2  Viewing the alarm history 
 
The following describes the procedure to confirm the current alarm condition or the alarms occurred in past time.   
■ Procedure ■ 
1
1
1
.
.
.
 
 
 
Press   MENU   , and through hierarchical menus, 
select the 8.2 Alarm information. 
According to the alarm occurring condition, the screen 
will be displayed as shown at right. 
 
 
 
 
The displayed alarm information is formatted as follows. 
[Alarm Date and Time] 
[Alarm Number], [Popup Information] 
 
 
 
 
 
2
2
2
.
.
.
 
 
 
To check the alarm history, press ENT. 
After the popup screen at right will be displayed, select OK. 
 
 
 
 
 
3
3
3
.
.
.
 
 
 
The alarm history will be displayed. 
The latest up to 10 histories are stored. 
If necessary, scroll with the jog dial. 
 
 
The displayed alarm history is formatted as follows. 
[Number] [Alarm and Recovery Date and Time] [Alarm Number]  
[A: Alarm/V: Recovery] [Popup Information] 
 
8.2)Alarm information 
 
 
        No data 
 
 
 
 
Press ENT to view alarm history. 
8.2)Alarm information 
 
'06-12-31 23:59 
001,TRCVR high temp 
004,WKR PLL unlock 
 
 
 
Press ENT to view alarm history. 
 
 View alarm history? 
 
 [ OK ]   [Cancel] 
Alarm history 
 
1.'06-12-31 23:59 001 A 
   TRCVR high temp 
2.'06-12-31 23:59 004 A 
   WKR PLL unlock 
3.'06-11-25 06:33 000 V 
   TRCVR VSWR 
Note 
Note 
8.2)Alarm information 
 
'06-12-31 23:59 
001,TRCVR high temp 
004,WKR PLL unlock 
 
 
 
Press ENT to view alarm history. 
(In the case of alarms occurring) 
(In the case of no current alarm)