3
3 – 48
3.3
3.3.23.7   Setting Vector Time
This function is used to set the vector length.
The default setting is 6 minutes.
The vector time information is always displayed on the screen.
Procedures
1. Press the 
SUB
MENU
 key to open the SUBMENU.
2. Press the 
3
 key to open the RADAR #3 menu.
3. Press the 
3
 key to open the EPA menu.
4. Press the 
1
 key to select VECTOR TIME.
5. Press the 
1
 key to enable the vector time to be entered.
6. Enter the vector time (0 to 60 minutes) using numeric keys (
0
 to
9
).
7. Press the 
ENT
 key to confirm the setting.
Exit
8. Press the 
SUB
MENU
 key.
or
Procedures
Press the 
VECT+
 or 
VECT–
DEST
 key to increase or decrease the vector time every
minute.
EPA
1. VECTOR TIME 6MIN (0-60 MIN)
2. PLOT NUMBER OFF
ON
3. LIMITS   CPA 1NM (0.1-9.9 NM. )
TCPA 15MIN (1-99 MIN)
4. AUDIBLE WARNING OFF
ON
5. DISPLAY OF CPA RING OFF
ON
EPA 0.  PREV
Attention