8 – 43
8.5
8.5.5.2 Checking DGPS Receiving Status
Checking the DGPS receiving status. When no beacon receiver is connected, or receiver or cable failure
occurs, the message "BEACON RCV NONCONNECT" appears.
• Items
Frequency: Displays the frequency of the beacon station currently received.
Baud rate: Displays the baud rate of the beacon station currently received.
RSSI: Displays the receiving intensity of the beacon station currently received. When it is 100
or lower, the beacon may not be received.
Procedures
1. Press the
SUB
MENU
key to open the SUB MENU.
2. Press the
9
key twice to open the INIT SET #2 menu.
3. Press the
8
key to open the SETTING DGPS/DGPS STATUS menu.
Exit
4. Press the
SUB
MENU
key.
Setting DGPS
//
//
/ DGPS Status
SETTING DGPS / DGPS STATUS
Press an item number key.
0. PREVIOUS NEMU
1. MODE AUTO MANUAL
2. FREQUENCY xxx. x kHz
3. BAUD RATE (BPS) 50 100 200
4. SET DATA
1kHz 500Hz
5. SEND DATA
6.
7.
8.
9.
STATUS BEACON RCV CONNECT
FREQUENCY –––––––– kHz
BAUD RATE ––––– BAUD
RSSI –––––
To close this menu, Press (SUB MENU) key.