EX8208 switches—Replace slot-number with a value from 0 through 7 (line
card).
EX8216 switches—Replace slot-number with a value from 0 through 15 (line
card).
QFX Series:
QFX3500,QFX3600, QFX5100, and OCX Series standalone switches—Replace
slot-number with 0. In the command output, FPC refers to a line card. The FPC
number equals the slot number for the line card.
QFabric systems—Replace slot-number with any number between 0 and 15. In
the command output, FPC refers to a line card. The FPC number equals the slot
number for the line card.
all-members—(MX Series routers and EX Series switches only) (Optional) Display PIC
information for all member routers in the Virtual Chassis configuration.
interconnect-device name—(QFabric systems only) (Optional) Display PIC information
for a specified Interconnect device.
lcc number—(TX Matrix and TX Matrix Plus routers only) (Optional) On a TX Matrix router,
display PIC information for a specified T640 router (or line-card chassis) that is
connected to the TX Matrix router. On a TX Matrix Plus router, display PIC information
for a specified router (line-card chassis) that is connected to the TX Matrix Plus
router.
Replace number with the following values depending on the LCC configuration:
0 through 3, when T640 routers are connected to a TX Matrix router in a routing
matrix.
0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a
routing matrix.
0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D
SIBs in a routing matrix.
0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with
3D SIBs in a routing matrix.
local—(MX Series routers and EX Series switches only) (Optional) Display PIC information
for the local Virtual Chassis member.
member member-id—(MX Series routers and EX Series switches only) (Optional) Display
PIC information for the specified member of the Virtual Chassis configuration. Replace
member-id with a value of 0 or 1.
node-device name—(QFabric systems only) (Optional) Display PIC information for a
specified Node device.
pic-slot slot-number—Display information about the PIC in this particular PIC slot. For
routers, replace slot-number with a value from 0 through 3. For EX3200 and EX4200
389Copyright © 2016, Juniper Networks, Inc.