Table 31: PTX1000 Chassis Alarm Messages
Recommended ActionCLI MessageAlarm TypeComponent
Replace the fan module and report the
failure to customer support.
Fan FailureMajor (red)Fans
Check the system log for one of the
following messages and report the
error message to customer support:
CM ENV Monitor: Get fan speed
failed.
fan-number is NOT spinning @
correct speed, where fan-number
can be 1, 2, or 3.
Fan I2C Failure
Remove and check the fan module for
obstructions, and then reinsert the fan
module. If the problem persists,
replace the fan module.
Fan fan-number Not Spinning
Check the system log for the message
fan-number Absent, where fan-number
can be 1, 2, or 3.
Install the fan module.
Fan/Blower AbsentMinor (yellow)