Maintaining the PTX1000 Fan Modules
IN THIS SECTION
Removing a Fan Module from the PTX1000 | 98
Installing a Fan Module in the PTX1000 | 99
Removing a Fan Module from the PTX1000
The fan modules in a PTX1000 are hot-removable and hot-insertable field-replaceable units (FRUs)—you
can remove and replace them without powering off the PTX1000 or disrupting routing functions.
CAUTION: Replace the fan module within 30 seconds of removal to prevent chassis
overheating. Before removing the fan module, ensure you have a replacement fan
module available.
Before you remove a fan module from a PTX1000, ensure that you have taken the necessary precautions
to prevent electrostatic discharge (ESD) damage (see “Prevention of Electrostatic Discharge Damage” on
page 161).
Ensure that you have the following parts and tools available:
ESD grounding strap
Antistatic bag or an antistatic mat
Phillips (+) screwdriver, number 1
To remove a fan module from a PTX1000 (see Figure 38 on page 99):
1. Place the antistatic bag or the antistatic mat on a flat, stable surface.
2. To prevent damage to the equipment caused by static discharge, attach an electrostatic discharge (ESD)
grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3. Using the Phillips screwdriver, loosen the locking screw (3 or 4 turns).
4. Grasp the handle on the fan module and squeeze the outside of the handle to release the module.
98