Table 31: PTX1000 Chassis Alarm Messages (continued)
Recommended ActionCLI MessageAlarm TypeComponent
Check the system log for the following
message and report it to customer
support:
Temp sensor sensor-number failed,
where sensor-number ranges from 1
through 10.
sensor-location Temp Sensor FailMajor (red)Temperature
sensors
Check environmental conditions and
alarms on other devices. Ensure that
environmental factors (such as hot air
blowing around the equipment) do not
affect the temperature sensor. If the
condition persists, the device might
shut down.
sensor-location Temp Sensor Too Hot
For information only. Check
environmental conditions and alarms
on other devices. Ensure that
environmental factors (such as hot air
blowing around the equipment) do not
affect the temperature sensor.
sensor-location Temp Sensor Too
Warm
Minor (yellow)
Clean up the system file storage space
on the device. For more information,
see request system storage cleanup.
RE RE number /var partition is fullMajor (red)Routing Engine
Clean up the system file storage space
on the device. For more information,
see request system storage cleanup.
RE RE number /var partition usage is
high
Minor (yellow)
Check whether a cable is connected
to the management Ethernet interface,
or whether the cable is defective.
Replace the cable, if required.
If the problem cannot be resolved,
open a support case.
Management Ethernet 1 Link DownMajor (red)Management
Ethernet interface