User Manual B-Net 93 60 Set-up
01/2006 © Kaba Benzing GmbH 45
6.2.5 Subterminal
Hardware requirements:
The terminal must be equipped with option BEX302 (interface RS485).
The subterminals must be connected at the BEX101 mother board, please
refer to chapter
5.6.6
Other requirement:
To support subterminals a corresponding license key is required; refer to
chapter
7.3.6.8.
Settings in the service module:
Hardware Settings/SubLine, refer to chapter
7.3.7.5.
Sub line 1: Enabled
• Interface: COM1
Hardware settings/serial line communication parameter,
please refer to chapter
7.3.7.2.
• COM 1: Enabled
Bits per second: 19200
• Data bits: 7
• Parity EVEN
• Stop bits: 1