01/2006  © Kaba Benzing GmbH  49
 
 
 
7.2  Access to the service module 
 
Access to the FTP server and the HTML server of the Service Module takes place 
via the BECO’s Ethernet connection. 
 
7.2.1 First access 
 
The default IP address 123.0.0.2 is preset on the BECO 
•  with ex factory delivery 
•  after the start of the service mode with simultaneous setting of the default IP 
address. For this purpose, press and hold the service button for at least 12 
seconds.  
(Details about the individual start options are explained in chapter 
6.3). 
The network setting in the service PC must be configured accordingly, e.g. IP 
address 123.0.0.1. The Service PC must be in the same network segment. 
For initial startup, the service PC is connected directly to the BECO via an Ethernet 
cross over cable (crossed RJ-45 cable). 
 
7.2.2  Access after executed network parameter setting 
 
After startup, the BECO’s service module can be called up via the entered IP 
address. 
 
 
Remark 
A newly set IP address will be active after the device has been rebooted. 
 
 
7.3 Service functions 
 
The communication with the menu-driven service functions of the BECO Service 
Module takes place via an HTTP browser. 
 
7.3.1  Demands on the HTTP browser 
 
User dialogs for the modification of settings (e.g., date, addresses) are carried out 
in Java applets.  
The HTTP browser used must therefore support Java applets. 
An installed and activated Sun JRE version as of 1.4.2_03 is required. 
 
7.3.2  Call of service functions 
 
As soon as the BECO is physically connected with the service PC, the service 
functions can be accessed with the help of the HTTP browser. For this purpose 
simply enter the BECO’s IP address (default 123.0.0.2). 
 
 
Remark 
Please consider, that with an active IP address filter the proxy server must be 
avoided where applicable.