Do you have a question about the Kaye LTR -90 and is the answer not in the manual?
Identifies conditions and procedures dangerous to the user and potential damage to equipment.
Provides contact details for customer service and technical support in North America and Europe.
Details the procedure for sending the Calibrator for calibration or repair services.
Introduces the LTR-90 Ultra-Cool Dry Well Calibrator and its primary function.
Details the instrument's specifications, including part numbers, temperature range, accuracy, stability, and operating conditions.
Provides instructions for unpacking the instrument and checking for any shipping damage.
Guides on selecting an appropriate location and positioning the calibrator for safe and optimal use.
Explains how to connect the calibrator to a suitable mains power outlet.
Details the procedure for powering on the calibrator and monitoring the startup sequence.
Guides the user through the steps to change the display language setting on the calibrator.
Explains how to adjust the display contrast for better readability.
Describes how to enable or disable the audible beep sound associated with key presses.
Details the user access security levels, password protection, and how to change them.
Identifies and describes the main panels and features of the LTR-90 calibrator.
Details the functions of the display screen and the buttons on the calibrator's control panel.
Describes the connectors and ports for power input and remote communication interfaces.
Explains the function and features of the constant temperature block where sensors are inserted.
Details the startup sequence and describes the indicators displayed on the calibrator's main operational screen.
Explains how set-point temperatures are defined and managed, whether automatically via Validator or manually.
Provides instructions for setting up the calibrator, including placement and power connection.
Details the process of calibrating sensors using the LTR-90 and Kaye Validator for accurate measurements.
Explains the correct procedures for installing and removing the calibration inserts from the calibrator wells.
Details the correct method for inserting and removing probes into the calibrator wells, including best practices for stability.
Explains how to navigate the main menu and its submenus using the calibrator's buttons.
Describes the functions and submenus related to setting up temperature parameters within the calibrator.
Details the specific settings within the Temperature Setup menu, including Scan Rate, Stable Limit, and Stable Alarm.
Explains the Soft and Hard Cutout limit parameters that protect probes and the calibrator from excessive temperatures.
Provides information on the cooler status, including temperature, self-test results, and heat balance.
Explains how to set temperature set-points, including manual setting and using presets.
Guides the user through the steps to manually set a target temperature (SETPOINT) on the calibrator.
Explains how to load and use pre-configured temperature set-points stored in the calibrator.
Details the procedure for modifying or updating existing preset temperature set-points on the calibrator.
Describes how to cancel or halt an ongoing temperature change process on the calibrator.
Explains how to configure the soft cutout, an upper-heat limit to protect calibration probes.
Details the procedure to exit Cutout Mode and reset the calibrator after an over-temperature condition.
Introduces the functionality for creating, running, and stopping automated calibration programs or tests.
Provides step-by-step instructions on how to initiate and run an automated program on the calibrator.
Explains the procedure to halt or stop an automated program that is currently running on the calibrator.
Details the Program Menu, which provides access to automated and manual program settings for calibration.
Explains the settings within the Program Setup menu, focusing on test status for programs.
Describes the Ramp/Soak setup menu for configuring multi-step temperature programs, including soak times and cycles.
Introduces the System menu for configuring display, communications, password, and calibration settings.
Details the display settings within the System menu, such as language, decimal format, and key beep.
Explains the communication settings, including baud rate and line feed, for connecting the calibrator to other devices.
Accesses calibration parameters set at the factory, protected by password, for maintaining instrument accuracy.
Provides information about the calibrator, such as model number, serial number, firmware version, and calibration date.
Introduces the chapter's focus on servicing and maintaining the calibrator.
Covers essential maintenance procedures for the calibrator, including cleaning and moisture removal.
Provides instructions on how to clean the exterior surfaces of the calibrator.
Details the steps for removing moisture buildup from the well and probe holes, especially after cold operation.
Explains the importance and procedure for regularly cleaning the calibration inserts to prevent deposit buildup.
Provides instructions and safety precautions for replacing the product fuse in the calibrator.
Offers a troubleshooting chart to help identify and resolve common problems encountered with the calibrator.
| Brand | Kaye |
|---|---|
| Model | LTR -90 |
| Category | Test Equipment |
| Language | English |