OS04 Language Parameter address 0x2384
Value Description
0…7 Use the keys ▲ and ▼ to choose one of the following languages:
0: English
1: German
2: American
3:
Francais
4: Italiano
5: Russian
6: Espanõl
7: Custom
ENTER selects the desired language and returns to the submenu.
OS05 Contrast Parameter address 0x2381
Value Description
-50…50 Sets the contrast of the LCD display.
Press ENTER to change into the input mode in order to change the parameter value.
Use the keys ▲ and ▼ to adjust the contrast in a range of -50…50.
OS06 Dene font size Parameter address 0x2382
Value Description
0…4 The font size determines the complete menu view in the display.
Press ENTER to change into the input mode in order to change the parameter value.
Use the keys ▲ and ▼ to choose one of the following font sizes:
8, 10, 13, 16, 24 pixel
ENTER selects the desired font size.
OS07 Dene font size 2 Parameter address 0x2383
Value Description
0…4 Determines the font size of the parameter values.
OS08 Backlight mode Parameter address 0x2385
Value Description
0…2 The menu item determines the behavior for the backlight of the LC display.
Press ENTER to change into the input mode in order to change the parameter value.
Use the keys ▲ and ▼ to choose one of the following adjustments:
0: o󰀨 → generally o󰀨
1: on → generally on
2: Automatically → on when pressing a key; o󰀨 after 30 seconds if no key is pressed
30
NAVIGATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB F6 Series and is the answer not in the manual?

KEB F6 Series Specifications

General IconGeneral
Communication InterfacesRS-485, Modbus RTU, CANopen
ProtectionOvercurrent, overvoltage, undervoltage, short circuit
Operating Temperature-10°C to +40°C
HumidityUp to 95% relative humidity, non-condensing
Control Modessensorless vector control (ASCL), closed-loop vector control (encoder feedback)

Related product manuals