6.7.2 Fieldbus parameters (Fb)
Fb00 MAC address Parameter address 0x2280
Value Description
The MAC address (Media Access Control) is formed of 6 bytes. Only the lowest 4 bytes
are displayed at "FAxxxxxx“. This address is assigned by the manufacturer and cannot
be changed.
Fb01 IP address Parameter address 0x2280
Value Description
The IP address consists of 4 bytes and is the clear identication of one internet partici-
pant. In case of doubt, the network administrator gives the address to be adjusted.
Fb02 Active IP address Parameter address 0x2282
Value Description
Displays the value of the currently used IP address.
Fb05 IP error counter Parameter address 0x2285
Value Description
Serves for the diagnosis of the IP protocol stack.
Fb06 TCP connections Parameter address 0x2286
Value Description
Displays the number of active TCP/IP connections.
Fb07 UDP connections Parameter address 0x2287
Value Description
Displays the number of active UDP connections.
Fb09 Data port password Parameter address 0x2289
Value Description
0…2147483647 Denes the write protection password for the access via port 8000. If the password
is active, this password must rst be entered again for a write access. Error message
"operation not possible" is displayed in case of locked data port write access. Value
‘0’ switches o󰀨 the write protection password (only possible if the active password is
correct entered).
Read:
-1: Inactive
-2: Active
Write:
0: Delete password
> 0: Password set / enter
If for 30 seconds there is no communication with the operator, the password
must be entered again.
32
NAVIGATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB F6 Series and is the answer not in the manual?

KEB F6 Series Specifications

General IconGeneral
Communication InterfacesRS-485, Modbus RTU, CANopen
ProtectionOvercurrent, overvoltage, undervoltage, short circuit
Operating Temperature-10°C to +40°C
HumidityUp to 95% relative humidity, non-condensing
Control Modessensorless vector control (ASCL), closed-loop vector control (encoder feedback)

Related product manuals