MasterMig 353, 355
Operating manual- EN
Remote min.
Defined by the active welding program Minimum and maximum limits for the
remote wire feed speed adjustment.
Remote max.
Defined by the active welding program
Cable calibration
(MIG only)
Start/Cancel Calibration information on the previous
calibration is also shown. Refer to "Cal-
ibrating welding cable" on page33 for
cable calibration.
Water cooler
OFF/Auto/ON
Default = Auto
When ON is selected, the coolant is cir-
culated continually, and when Auto is
selected, the coolant is circulated only
during welding.
Cycle timer
ON/OFF
Default = OFF
A welding function that automatically
produces a weld of a predefined dur-
ation.
- Time
0.0 ... 60.0 s
Default = 2.0 s
WF end step
OFF/ON
Default = OFF
Wire feed end step feature prevents the
filler wire from sticking to the contact tip
when the welding ends.
Subfeeder
Subfeeder model / OFF
Default = OFF
If a compatible subfeeder is connected,
select the subfeeder from the list.
Compatible subfeeders:
SuperSnake GTX 10 m, 15 m, 20 m, 25 m.
Note: For the best possible welding result
when using the pulse and MAX welding
processes with a subfeeder device, we
recommend a maximum subfeeder cable
length of 10 meters (SuperSnake GTX 10
m). This recommendation assumes that
you are using a 5-meter welding gun
cable and a 15-meter earth return cable
together with the subfeeder. In some
cases, it is possible to weld with pulse
and MAX welding processes with a 15-
meter subfeeder device, but a test weld is
advised.
Arc verification
1...365
Default = 0 (OFF)
This defines the number of days to the
next device verification.
Weld data
0...10 s, step 1
Default = 5 s
This defines how long the weld data sum-
mary is shown after each weld.
Safe wire inch
(MIG only)
OFF/ON
Default = ON
When ON, and the arc doesn't ignite, the
filler wire is fed 5 cm. When OFF, 5 m of
filler wire is fed.
Gas guard (MasterMig 355 only)
ON/OFF
Default = OFF
Gas guard prevents welding without
shielding gas.
Voltage display
Arc voltage / Terminal voltage
Default = Arc voltage
This defines which is shown on the con-
trol panel display, arc or terminal voltage.
PIN code
ON/OFF 4-digit PIN code for locking the control
panel after 30 s of inactivity. PIN lock does
not prevent welding, browsing Powerlog
levels or selecting memory channel.
Device info
Shows information on the device and its
usage.