SENSe Subsystem
Sense commands control the current measurement ranges and window as well as the data
acquisition sequence.
SENSe
:AHOur
:RESet Resets the amp-hour or watt-hour measurement to zero.
:BBR
:PERiod <value> Sets the recording period of the black box recorder in seconds.
:CURRent
[:DC]
:RANGe
[:UPPer] <value> Selects a DC current measurement range.
:AUTO 0|OFF|1|ON Enables or disables seamless measurement auto ranging.
:ELOG
:CURRent
[:DC]
:RANge
[:UPPer] <value> Selects the Elog current measurement range.
:AUTO 0|OFF|1|ON Enables or disables Elog seamless measurement autoranging.
:FUNCtion
:CURRent 0|OFF|1|ON Enables/disables current data logging.
:MINMax 0|OFF|1|ON Enables/disables min/max current data logging.
:VOLTage 0|OFF|1|ON Enables/disables voltage data logging.
:MINMax 0|OFF|1|ON Enables/disables min/max voltage data logging.
:PERiod <value> Sets the integration time of an Elog measurement.
:FAULt
:STATe 0|OFF|1|ON Enables or disables remote sense fault detection.
:SWEep
:NPLCycles <value> Sets the measurement time in number of power line cycles.
:OFFSet
:POINts <value> Defines the offset in a data sweep for triggered meas-
urements.
:POINts <value> Defines the number of points in a measurement.
:TINTerval <value> Defines the time period between measurement samples.
:THReshold<1|2|3|4>
:AHOur
[:LEVel] <value> Sets the amp-hour level for comparator 1,2,3, or 4.
:CURRent
[:LEVel] <value> Sets the current level for comparator 1,2,3, or 4.
:FUNCtion
VOLT|CURR|POW|AHO|WHO
Sets the sensing function for comparator 1,2,3, or 4.
:OPERation GT|LT Sets the comparison type for comparator 1,2,3, or 4.
Keysight N6900/N7900 Series Operating and Service Guide 256
6 SCPI Programming Reference