EasyManuals Logo

Keysight Technologies N6972A with Option 301 User Manual

Keysight Technologies N6972A with Option 301
358 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #256 background imageLoading...
Page #256 background image
SENSe Subsystem
Sense commands control the current measurement ranges and window as well as the data
acquisition sequence.
SENSe
:AHOur
:RESet Resets the amp-hour or watt-hour measurement to zero.
:BBR
:PERiod <value> Sets the recording period of the black box recorder in seconds.
:CURRent
[:DC]
:RANGe
[:UPPer] <value> Selects a DC current measurement range.
:AUTO 0|OFF|1|ON Enables or disables seamless measurement auto ranging.
:ELOG
:CURRent
[:DC]
:RANge
[:UPPer] <value> Selects the Elog current measurement range.
:AUTO 0|OFF|1|ON Enables or disables Elog seamless measurement autoranging.
:FUNCtion
:CURRent 0|OFF|1|ON Enables/disables current data logging.
:MINMax 0|OFF|1|ON Enables/disables min/max current data logging.
:VOLTage 0|OFF|1|ON Enables/disables voltage data logging.
:MINMax 0|OFF|1|ON Enables/disables min/max voltage data logging.
:PERiod <value> Sets the integration time of an Elog measurement.
:FAULt
:STATe 0|OFF|1|ON Enables or disables remote sense fault detection.
:SWEep
:NPLCycles <value> Sets the measurement time in number of power line cycles.
:OFFSet
:POINts <value> Defines the offset in a data sweep for triggered meas-
urements.
:POINts <value> Defines the number of points in a measurement.
:TINTerval <value> Defines the time period between measurement samples.
:THReshold<1|2|3|4>
:AHOur
[:LEVel] <value> Sets the amp-hour level for comparator 1,2,3, or 4.
:CURRent
[:LEVel] <value> Sets the current level for comparator 1,2,3, or 4.
:FUNCtion
VOLT|CURR|POW|AHO|WHO
Sets the sensing function for comparator 1,2,3, or 4.
:OPERation GT|LT Sets the comparison type for comparator 1,2,3, or 4.
Keysight N6900/N7900 Series Operating and Service Guide 256
6 SCPI Programming Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N6972A with Option 301 and is the answer not in the manual?

Keysight Technologies N6972A with Option 301 Specifications

General IconGeneral
BrandKeysight Technologies
ModelN6972A with Option 301
CategoryPower Supply
LanguageEnglish

Related product manuals