1 kW Models 2 kW Models
120 V, 2 kWOutput Impedance
160 V, 2 kWOutput Impedance
Inductive Load Boundary
The following figures show the boundary limitation for inductive loads and for fast CV/CC mode
crossover operation. Operation above the inductive load boundary may result in output instability. The
boundary limit represents operating conditions including a 20% current overshoot. Note that
increased load resistance allows increased output inductance.
1 kW Inductive Load Boundary
2 kW Inductive Load Boundary
1 Quick Reference
58 Keysight N6900/N7900 Series Operating and Service Guide