Configuring Signal Routing
This section explains how to use the Power Assistant to configure signal routing.
Routing Signals
Downloading the Routing
Saving the Routing File
Viewing the SCPI Commands
Source Icon Descriptions
Operator Icon Descriptions
Target Icon Descriptions
Signal Routing Examples
Routing Signals
Select the Trigger tab on top of the Power Assistant window. To get started configuring signal routing:
1. Select a signal source from the Source list on the left panel. For example click the Status icon to
place it onto the work area. Select CL+ from the Status dropdown list.
2. Select a signal target from the Target list on the right panel. For example click the Digital icon to
place it onto the work area. Select Pin 1 and Positive polarity from the Digital dropdown list.
3. Move the Status and Digital icons together until a dotted yellow line appears. Continue moving
the icons until the dotted line becomes solid.
As shown below, you have now routed the CL+ status signal to Pin 1 on the digital connector. Any time
a CL+ (positive current limit) occurs, the signal is routed to digital connector pin 1.
Keysight N6900/N7900 Series Operating and Service Guide 189
5 Using the Power Assistant Software