EasyManuals Logo

Keysight Technologies RP7900 Series User Manual

Keysight Technologies RP7900 Series
318 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #131 background imageLoading...
Page #131 background image
Specify any trigger signals that the list should generate
You can generate trigger signals that can be routed to other destinations. For example, you can use
trigger signals to trigger actions on any external equipment connected to the digital port. The
following figure gives an example of generating four trigger signals on the arbitrary list of Example 2.
Front Panel Menu Reference SCPI Command
Select Transient\List\Config.
Select the List Step number 4. To generate a trigger,
enter a 1 in the Tout Begin Step field.
Select the List Step numbers 0, 2, and 4. To generate
a trigger, enter a 1 in the Tout End Step field.
If zeroes are entered in the fields, no trigger is
generated for the step.
To program a trigger at the beginning of step 4:
LIST:TOUT:BOST 0,0,0,0,1,0
To program a trigger at the end of step 0, 2, and 4:
LIST:TOUT:EOST 1,0,1,0,1,0
Specify how many times you want the list to repeat
You can specify how many times you want the list (or pulse) to repeat. At reset, the list count is set to 1
repetition. Sending the INFinity parameter in the SCPI command makes the list repeat indefinitely.
Front Panel Menu Reference SCPI Command
Select Transient\List\Repeat.
Enter the number of list repetitions (2) and press
Select.
To program the list to repeat twice:
LIST:COUN 2
Specify how you want the list to end
Specify the output state after the list has completed. There are two choices: the output returns to the
value that was in effect before the list started, or the output remains at the value of the last list step.
Front Panel Menu Reference SCPI Command
Select Transient\List\Terminate.
Select either Return to Start, or Stop at Last Step
and press Select.
To return the output to the pre-list state:
LIST:TERM:LAST OFF
To keep the output at the end list state:
LIST:TERM:LAST ON
Keysight RP7900 Series Operating and Service Guide 131
4 Using the Regenerative Power System

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies RP7900 Series and is the answer not in the manual?

Keysight Technologies RP7900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelRP7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals