Specifications and Characteristics - RP793xA, RP794xA
Specifications - RP793xA, RP794xA
Supplemental Characteristics - RP793xA, RP794xA
Common Characteristics
Output Impedance Graphs
Inductive Load Boundary for Current Priority Mode
Capacitive Load Boundary for Voltage Priority Mode
Measurement Accuracy and Resolution
Excessive Dynamic Protection
Output Quadrants
Dimensions
Specifications - RP793xA, RP794xA
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to
40°C after a 30-minute warm-up period. Specifications apply at the output terminals, with the sense
terminals connected to the output terminals (local sensing).
Specification RP7931A,
RP7941A
RP7932A,
RP7942A
RP7933A,
RP7943A
RP7935A,
RP7945A
RP7936A,
RP7946A
DC Ratings
Voltage source:
Current source and sink:
Power:
0 to 20 V
0 to ±400 A
0 to ±5 kW
0 to 80 V
0 to ±125 A
0 to ±5 kW
0 to 20 V
0 to ±800 A
0 to ±10 kW
0 to 80 V
0 to ±250 A
0 to ±10 kW
0 to 160 V
0 to ±125 A
0 to ±10 kW
Output ripple & noise
CV peak-to-peak:
1
CV rms:
2
30 mV
3 mV
80 mV
8 mV
30 mV
3 mV
80 mV
8 mV
200 mV
20 mV
Load regulation
Voltage:
Current:
1 mV
25 mA
3 mV
13 mA
1 mV
50 mA
3 mV
25 mA
6 mV
13 mA
Voltage programming &
measurement accuracy
3
0.02% + 2 mV 0.02% + 8 mV 0.02% + 2 mV 0.02% + 8 mV 0.02% + 16 mV
Current programming &
measurement accuracy:
3
0.04% + 45 mA 0.03% + 13 mA 0.04% + 90 mA 0.03% + 25 mA 0.03% + 13 mA
Transient response
4
Recovery Time:
Settling band:
300 µs
0.2 V
300 µs
0.8 V
300 µs
0.2 V
300 µs
0.8 V
300 µs
1.6 V
1
From 20 Hz to 20 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
2
From 20 Hz to 10 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
3
Percent of value + offset; at 25°C ±5°C after a 30 minute warm-up; measurement NPLC=1; valid for 1 year, see Calibration Interval;
with a load lead voltagedrop of up to 1V per lead - see Wire Size for additional information about load lead voltagedrop
4
Time to recover to within the settling band following astep change from 40% to 90% of full load with a 35 μs current rise time
Keysight RP7900 Series Operating and Service Guide 35
1 Quick Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies RP7900 Series and is the answer not in the manual?

Keysight Technologies RP7900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelRP7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals