Supplemental Characteristics - RP793xA, RP794xA
Supplemental characteristics are not warranted but are descriptions of performance determined
either by design or by type testing. Supplemental characteristics are typical unless otherwise noted.
Characteristic RP7931A,
RP7941A
RP7932A,
RP7942A
RP7933A,
RP7943A
RP7935A,
RP7945A
RP7936A,
RP7946A
Minimum compliance limits
Voltage priority:
Current priority
1
:
±400 mA
0 and 20 mV
±125 mA
0 and 80 mV
±800 mA
0 and 20 mV
±250 mA
0 and 80 mV
±125 mA
0 and 160 mV
Voltage programming
Range:
Resolution:
0.02 to 20.4 V
191 µV
0.08 to 81.6 V
800 µV
0.02 to 20.4 V
191 µV
0.08 to 81.6 V
800 µV
0.16V to 163.2V
1.6 mV
Current programming
Range:
Resolution:
-408 A to 408 A
7.7 mA
-127.5 A to 127.5 A
2.5 mA
-816 A to 816 A
15.5 mA
-255 A to 255 A
5 mA
-127.5A to 127.5A
2.5 mA
Resistance programming
Range:
Resolution:
Accuracy:
0 to 0.098 Ω
0.8 µΩ
0.05% + 4 µΩ
0 to 1.25 Ω
9.8 µΩ
0.05% + 32 µΩ
0 to 0.049 Ω
0.4 µΩ
0.05% + 2 µΩ
0 to 0.625 Ω
4.8 µΩ
0.05% + 16 µΩ
0 to 2.5 Ω
19.6 µΩ
0.05% + 50 µΩ
Additional V-programming offset/ Ohm:
50 mV 15 mV 100 mV 30 mV 15 mV
Measurement range
Voltage:
Current:
-25 V to 25 V
-1014 A to 1014 A
-100 V to 100 V
-315 A to 315 A
-25 V to 25 V
-2028 A to 2028 A
-100 V to 100 V
-630 A to 630 A
-200 V to 200 V
-315 A to 315 A
Measurement digitization noise
2
Voltage:
Current:
4 mV
400 mA
20 mV
200 mA
4 mV
800 mA
20 mV
400 mA
40 mV
200 mA
Programming & measurement
tempCo
3
Voltage:
Current:
0.0015% +80 µV/°C
0.0075% +1.2mA/°C
0.0015% +300µV/°C
0.0025% +400µA/°C
0.0015% +80 µV/°C
0.0075% +2.3mA/°C
0.0015% +300µV/°C
0.0025% +800µA/°C
0.0015%+600µV/°C
0.0025%+400µA/°C
Output current ripple & noise (CC rms): 200 mA 70 mA 200 mA 70 mA 50 mA
Common mode current
CC rms:
CC peak-to-peak:
2 mA
20 mA
2.5 mA
24 mA
2 mA
20 mA
2.5 mA
24 mA
3.5 mA
30 mA
Overvoltage protection
4
Maximum setting:
Response time:
Accuracy:
24 V
< 30 µs
0.02% + 2 mV
96 V
< 30 µs
0.02% + 8 mV
24 V
< 30 µs
0.02% + 2 mV
96 V
< 30 µs
0.02% + 8 mV
192 V
< 30 µs
0.02% + 16 mV
Voltage Programming Speed, no load
5
Rise/fall time 10% to 90% of step:
Settling time to 0.1% of step:
80 µs
810 µs
75 µs
480 µs
80 µs
810 µs
75 µs
480 µs
75 µs
550 µs
Voltage Programming Speed, full load
6
Rise/fall time 10% to 90% of step:
Settling time to 0.1% of step:
140 µs
4.2 ms
130 µs
1.35 ms
140 µs
4.2 ms
130 µs
1.35 ms
170 µs
1.35 ms
Current Up/down Programming Speed
7
Rise/fall time 10% to 90% of step:
Settling time to 0.1% of step::
300 µs
960 µs
180 µs
500 µs
300 µs
960 µs
180 µs
500 µs
190 µs
550 µs
1 Quick Reference
36 Keysight RP7900 Series Operating and Service Guide