E8257D/67D, E8663D PSG Signal Generators Service Guide
Assembly Replacement
A13 I/Q MUX (E8267D Standard or with Option H16/016) (Serial Prefixes >=US4722/MY4722)
3-34
A13 I/Q MUX (E8267D Standard or with Option H16/016) (Serial Prefixes >=US4722/MY4722)
Tools Required
T–10 driver
needle–nose pliers
Removal Procedure
Refer to Figure 3- 19 for this procedure.
1. Disconnect the power cord.
2. Remove the covers from the signal generator. Refer to “Outer Instrument Cover” on page 3- 4 and “Inner
Instrument Cover” on page 3- 6.
3. Position the signal generator with the front panel facing you.
4. Using the T–10 driver, remove the four screws from the Baseband Generator cover.
5. Using the needle–nose pliers, disconnect the following flexible cables:
W63 from A13J5
W62from A13J6
W49 from A13J7
W50 from A13J8
W131 from A13J9
W133 from A13J10
W59 from A13J11
W58 from A13J12
W57 from A13J13
W56 from A13J14
W123 from A13J15
W124 from A13J16
W127 from A13J17
W128 from A13J18
W125 from A13J19
W126 from A13J20
W129 from A13J21
W130 from A13J22
6. Lift the retention levers and disconnect the A13 I/Q MUX from the A31 Motherboard.
7. Lift the A13 I/Q MUX out of the slot.
Replacement Procedure
1. Reverse the order of the removal procedure. (See the internal cover overlay for cable color codes.)
2. Perform the post–repair adjustments and performance tests that pertain to this removal procedure.