[SOURce:]ARB:SEQuence:STEP:CURRent:RAMP:RTIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:RAMP:RTIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:RAMP:RTIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:RAMP:RTIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:RAMP:RTIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:RAMP:RTIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:RAMP:RTIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:RAMP:RTIMe? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the rise time of the ramp in seconds for Arb sequence steps.
Parameter Typical Return
0 262.144 | MIN | MAX, *RST 1 <rise time>
Step 0 - 99, *RST 0 (none)
Programs a rise time for the current ramp: ARB:CURR:RAMP:RTIM 10,(@1)
Programs a rise time for the voltage ramp: ARB:VOLT:RAMP:RTIM 10,(@1)
Programs a rise time for the power ramp: ARB:POW:RAMP:RTIM 10,(@1)
Programs a rise time for the resistance ramp: ARB:RESISTANCE:RAMP:RTIM 10,(@1)
Programs a rise time for step 0: ARB:SEQ:STEP:CURR:RAMP:RTIM 10, 0,(@1)
[SOURce:]ARB:CURRent:RAMP:STARt[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:CURRent:RAMP:STARt[:LEVel]? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:VOLTage:RAMP:STARt[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:VOLTage:RAMP:STARt[:LEVel]? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:POWer:RAMP:STARt[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:POWer:RAMP:STARt[:LEVel]? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:RESISTANCE:RAMP:STARt[:LEVel] <value>, (@<chanlist>)
[SOURce:]ARB:RESISTANCE:RAMP:STARt[:LEVel]? [MIN|MAX,] (@<chanlist>)
Specifies the initial current, voltage, power, or resistance level before the ramp occurs.
[SOURce:]ARB:SEQuence:STEP:CURRent:RAMP:STARt[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:RAMP:STARt[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:RAMP:STARt[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:RAMP:STARt[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:RAMP:STARt[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:RAMP:STARt[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:RAMP:STARt[:LEVel] <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:RAMP:STARt[:LEVel]? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the initial current, voltage, power, or resistance level before the ramp occurs for Arb
sequence steps.