[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:DWELl:POINts? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:DWELl:POINts? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:UDEFined:DWELl:POINts? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:UDEFined:DWELl:POINts? <step#>, (@<chanlist>)
Returns the number of dwell points in the user-defined Arb for Arb sequence steps.
Parameter Typical Return
(none) <number of points>
Step 0 - 99, *RST 0 (none)
Returns the number of current dwell points: ARB:CURR:UDEF:DWEL:POIN? (@1)
Returns the number of voltage dwell points: ARB:VOLT:UDEF:DWEL:POIN? (@1)
Returns the number of power dwell points: ARB:POW:UDEF:DWEL:POIN? (@1)
Returns the number of resistance dwell points: ARB:RESISTANCE:UDEF:DWEL:POIN? (@1)
Returns the number of dwell points for step 0: ARB:SEQ:STEP:CURR:UDEF:DWEL:POIN? 0,(@1)
[SOURce:]ARB:CURRent:UDEFined:LEVel <value>{<,value>},(@<chanlist>)
[SOURce:]ARB:CURRent:UDEFined:LEVel? (@<chanlist>)
[SOURce:]ARB:VOLTage:UDEFined:LEVel <value>{<,value>},(@<chanlist>)
[SOURce:]ARB:VOLTage:UDEFined:LEVel? (@<chanlist>)
[SOURce:]ARB:POWer:UDEFined:LEVel <value>{<,value>},(@<chanlist>)
[SOURce:]ARB:POWer:UDEFined:LEVel? (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:LEVel <value>{<,value>},(@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:LEVel? (@<chanlist>)
Specifies the level of each current, voltage, power, or resistance point in a user-defined Arb. A
comma-delimited list of up to 511 points may be programmed.
[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:LEVel <value>{<,value>}, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:LEVel? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:LEVel <value>{<,value>}, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:LEVel? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:UDEFined:LEVel <value>{<,value>}, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:UDEFined:LEVel? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:UDEFined:LEVel <value>{<,value>}, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:UDEFined:LEVel? <step#>, (@<chanlist>)
Specifies the level of each current, voltage, power, or resistance point in a user-defined Arb for Arb
sequence steps. The last value in the sequence is the step number.