OUTPut[:STATe]:COUPle:DOFFset:MODE AUTO|MANual
OUTPut[:STATe]:COUPle:DOFFset:MODE?
Specifies the mode that determines where the output coupling delay value comes from when outputs
are synchronized. This parameter is saved in non-volatile memory.
AUTO - The power system automatically calculates the maximum delay offset value for all output
channels in the mainframe.
MANual - The power system uses the delay offset value set by OUTPut:COUPle:DOFFSet.
Parameter Typical Return
AUTO|MANual, *RST AUTO AUTO or MAN
Sets the delay offset mode to manual: OUTP:COUP:DOFF:MODE MAN
l When this command is sent, all channels in the unit will go to the output off state.
OUTPut[:STATe]:COUPle:MAX:DOFFset?
Returns the largest delay offset that is required for the output channels installed in this mainframe. As
a minimum, the OUTPut:COUPle:DELay:OFFSet value must be set to the maximum delay offset
returned for any coupled output.
Parameter Typical Return
(none) <offsetvalue>
Returns the maximum delay offset: OUTP:COUP:MAX:DOFF?
OUTPut[:STATe]:DELay:FALL <value>, (@<chanlist>)
OUTPut[:STATe]:DELay:FALL? [MIN|MAX,] (@<chanlist>)
OUTPut[:STATe]:DELay:RISE <value>, (@<chanlist>)
OUTPut[:STATe]:DELay:RISE? [MIN|MAX,] (@<chanlist>)
Specifies the delay in seconds that the instrument waits before turning the output on (rise) or off (fall).
This allows multiple channels to turn on or off in sequence. The output will not turn on or off until its
delay time has elapsed. This command affects on-to-off state transitions. It does NOT affect
transitions to off caused by protection functions. Delay times can be programmed from 0 to 1023
seconds with the following resolution:
Range in seconds Resolution Range in seconds Resolution
0 to 1.023E–4 100 nanoseconds 1.03E–1 to 1.023E+0 1 millisecond
1.03E–4 to 1.023E–3 1 microsecond 1.03E+0 to 1.023E+1 10 milliseconds
1.03E–3 to 1.023E–2 10 microseconds 1.03E+1 to 1.023E+2 100 milliseconds
1.03E–2 to 1.023E–1 100 microseconds 1.03E+2 to 1.023E+3 1 second
5 SCPI Programming Reference
266 Keysight N6700C Operating and Service Guide