Sets the remote over-voltage protection level.Units are in volts. If the remote voltage exceeds the
OVP level, the output is disabled and the Questionable Condition status register OV bit is set.
Parameter Typical Return
Positive: 0 ā 22|MIN|MAX, *RST MAX
Negative: -22 to 0|MIN|MAX, *RST MAX
<remoteover-voltage level>
Sets the over-voltage protection to 15 V: VOLT:PROT:REM 15, (@1)
Sets the over-voltage protection to -15 V: VOLT:PROT:REM:NEG -15, (@1)
l The remote OVP trips if the output terminal voltage is >1.5 V over the sense terminal voltage.
l MIN is the most negative value of the range. MAX is the least negative value of the range.
l The query returns the programmed voltage protection level in the form +n.nnnnnnE+nn for each
channel specified. Multiple responses are separated by commas.
[SOURce:]VOLTage:PROTection:TRACking[:STATe] 0|OFF|1|ON, (@<chanlist>)
[SOURce:]VOLTage:PROTection:TRACking[:STATe]? (@<chanlist>)
This command only applies to models N6752A, N6754A, and N6762A with .
Enables or disables the tracking over-voltage protection (OVP) function of the output channel.
Parameter Typical Return
0|OFF|1|ON, *RST OFF 0īorī1
Enable the tracking OVP function: VOLT:PROT:TRAC ON, (@1)
[SOURce:]VOLTage:PROTection:TRACking:OFFSet <value>, (@<chanlist>)
[SOURce:]VOLTage:PROTection:TRACking:OFFSet? [MIN|MAX,] (@<chanlist>)
This command only applies to models N6752A, N6754A, and N6762A with .
Set the tracking over-voltage protection (OVP) offset of the output channel. This lets you set an
overvoltage protection limit that is an offset from the programmed voltage. This is an addition to the
existing overvoltage limit. The tracking OVP threshold automatically tracks the programmed output
setting. The output voltage is monitored at the + sense and - sense terminals.
Parameter Typical Return
0 to maximum|MIN|MAX, *RST MAX
The maximum value is dependent on the voltage rat-
ing of the power module.
<tracking offset>
Sets the tracking OVP offsetto 2 V: VOLT:PROT:TRAC:OFFS 2, (@1)
5 SCPI Programming Reference
304 Keysight N6700C Operating and Service Guide