:FUNCtion
:SHAPe <function>, <step#>, (@chanlist) Creates a new sequence step
:PACing DWELl|TRIGger, <step#> (@chanlist) Specifies the type of pacing for the step
:RESISTANCE <function>, <step#> (@chanlist) Programs the steps in a resistance sequence
:VOLTage <function>, <step#> (@chanlist) Programs the steps in a voltage sequence
:TERMinate
:LAST 0|OFF|1|ON, (@chanlist) Sets the sequence termination mode
:TERMinate
:LAST 0|OFF|1|ON, (@chanlist) Sets the Arb termination mode
[SOURce:]
CURRent
[:LEVel]
[:IMMediate]
[:AMPLitude] <value>, (@chanlist) Sets the output current.
:TRIGgered
[:AMPLitude] <value>, (@chanlist) Sets the triggered output current
:LIMit
[:POSitive]
[:IMMediate]
[:AMPLitude] <value>, (@chanlist) Sets the positive current limit. (N678xA SMU, N6783A, N679xA)
:COUPle 0|OFF|1|ON, (@chanlist) Sets the current limit tracking state. (N678xA SMU)
:NEGative
[:IMMediate]
[:AMPLitude] <value>, (@chanlist) Sets the negative current limit. (N678xA SMU, N6783A-BAT)
:MODE FIXed|STEP|LIST|ARB, (@chanlist) Sets the transient mode.
:PROTection
:DELay
[:TIME] <value>, (@chanlist) Sets the over-current protection delay.
:STARt SCHange|CCTRans, (@chanlist) Specifies what starts the over-current protection delay timer.
:STATe 0|OFF|1|ON, (@chanlist) Enables/disables the over-current protection.
:RANGe <value>, (@chanlist) Sets the output current range.
:SLEW
[:POSitive]
[:IMMediate] <value>|INFinity, (@chanlist) Sets the current slew rate. (N678xA SMU, N679xA)
:MAXimum 0|OFF|1|ON, (@chanlist) Enables/disables the maximum slew rate override. (N678xA SMU,
N679xA)
:COUPle 0|OFF|1|ON, (@chanlist) Sets the current slew tracking state. (N679xA)
:NEGative
[:IMMediate] <value>|INFinity, (@chanlist) Sets the negative current slew rate. (N679xA)
:MAXimum 0|OFF|1|ON, (@chanlist) Enables/disables the maximum slew rate override. (N679xA)
1 Quick Reference
34 Keysight N6700C Operating and Service Guide