1 Introduction
Your Multimeter in Brief
42 U1271A/U1272A User’s Guide
Table 1-7 Keypad functions
Legend
Function when pressed for:
Learn
more on:
Less than 1 second More than 1 second
Sets the Null/Relative mode.
The displayed value is saved as a
reference to be subtracted from
subsequent measurements.
While in Null mode, press again
to view the stored reference value that
has been saved. The display will return
to normal after 3 seconds.
Pressing while the relative value
is being displayed will cancel the Null
mode.
Sets the Scale mode for the specified ratio
and unit display. (Only applicable for voltage
measurements.)
The most recently saved (or default)
ratio and unit will be shown on the
primary and secondary displays.
Press while the symbol is
flashing to cycle through the available
ratio and unit displays.
Press while the symbol is
flashing to save the selected ratio and
unit and to start the conversion, or
While the symbol is flashing, if
no activity is detected after 3 seconds,
the conversion will begin (with the
specified ratio and unit shown on the
primary display).
Press for more than 1 second to
cancel the Scale transfer mode.
page 108
and
page 110
Starts and stops the MaxMin recording.
Press again to cycle through
maximum (Max), minimum (Min),
average (Avg), and present
(MaxMinAvg) readings.
Press for more than 1 second to
exit this mode.
Starts and stops the Peak recording.
Press again to switch between
the maximum (Max) and
minimum (Min) peak readings.
Press for more than 1 second to
exit this mode.
page 112
and
page 114
Freezes the present reading in the display
( mode).
In TrigHold mode, press to
manually trigger the holding of the next
measured value.
Press for more than 1 second to
exit this mode.
Automatically freezes the present reading
once the reading is stable ( mode)
In AutoHold mode, the reading is
updated automatically once the reading
is stable and the count setting is
exceeded.
Press for more than 1 second to
exit this mode.
page 115
Switches between the dual-combination
displays (if available).
Exits the Hold, Null, MaxMin, Peak,
frequency test, and dual display modes.
page 179
S
c
a
l
e
N
u
l
l
S
c
a
l
e
N
u
l
l
S
c
a
l
e
N
u
l
l
S
c
a
l
e
N
u
l
l
H
z
%
m
s
L
o
g
S
c
a
l
e
N
u
l
l
P
e
a
k
M
a
x
M
i
n
P
e
a
k
M
a
x
M
i
n
P
e
a
k
M
a
x
M
i
n
P
e
a
k
M
a
x
M
i
n
P
e
a
k
M
a
x
M
i
n
A
u
t
o
T
r
i
g
H
o
l
d
A
u
t
o
T
r
i
g
H
o
l
d
A
u
t
o
T
r
i
g
H
o
l
d
A
u
t
o
T
r
i
g
H
o
l
d
Exit