SECTION 7
HIGH PRESSURE WATER
Nov 2002
p. 7-14
05126826
3. Inspect the poppet, spring, and guide for wear. Replace the spring
and guide if worn.
4. Apply a thin film of High Purity Goop to the sealing face of the gland
nut. Install the guide, spring, and poppet into the gland nut. Apply a
coating of food grade grease to the check poppet to hold it in place
when installing gland nut in sealing head.
5. Apply High Purity Goop to the gland nut threads. Install the gland
nut into the sealing head. The gland nut should be hand tightened
until there is a gap of 5mm (0.20”) between the gland nut and sealing
head. No threads should show. If the gap exceeds 5mm (0.20”), then
the poppet has slipped out of place, and the parts must be removed,
inspected and reassembled.
6. Using a 30mm (1-3/16”) crowfoot/torque wrench combination, torque
the gland nut to 88 Nm (65 ft-lbs.).
7. Reconnect high pressure and low pressure piping, collar and quick
disconnects per Section 7.2.1. Operate waterjet pump to verify HP
fittings do not leak, and that the HP water signal is normal (indicative
of normal check valve operation).