SECTION 8
ELECTRICAL SYSTEM
July 2003
p. 8-3
05130703
Replace Proximity Switch
1. Turn off waterjet pump, disconnect and LOCKOUT electric power.
2. Disconnect cable.
3. Unscrew bolts, remove proximity switch.
4. Install new switch. Install bolts.
5. Torque bolts to 16-18 Nm (140-160 in-lbs.).