10-10 A-61635 December 2010
However, since ALL AI batches share the same Auto Import Processing
Queue, if an AI batch from a different watch folder were to be next in the
queue, a batch separator would be inserted regardless of auto import setup
options.
AI batches in the Auto Import Processing Queue will be processed in first-in,
first-out order. There is no management facility for this queue. All AI batches
will be processed in their entirety, in sequence barring errors (see Error
handling, below).
When the entire batch has been processed, the original files will optionally be
copied into the archive.
Error handling When a batch is being processed, if a supported image file cannot be opened:
the bad file will be copied into the error cache,
a generic “error” image will substituted, and
the error count for the AI batch will be incremented.
If the error threshold defined in the batch setup has been reached, processing
of the batch will stop. A dialog box will be displayed with the following options:
- Ignore: move ahead to the next image. The batch will resume processing
until the next bad image is encountered.
- Abort: the remaining files in the batch will be copied into the error cache
and auto import will stop. Following an abort, when restarted, auto import
proceeds with the next batch in the queue. There is no automated recovery
procedure for batches copied into the error cache. The user will have to
locate and correct the bad files and manually reinsert the batch into the
watch folder.