Chapter 4 CVS-841/851
Installation
4.7 Inter-connections of the system
Display unit
J3: Temperature/speed sensor input,
buzzer output
J2: NMEA In/Out
(ST-80-1/ST-90-1/ST100-1)
J4: RS-232C In/Out
J5: Nav Data Input
(NMEA-0183)
J6:External sounder
DC Power Supply
(10.8 - 31.2VD)
TD Extension cable
VSV-2T11-3M
DC Power cable
CW-253-2M
AC/DC
Rectifier
PS-006
AC Power Supply
(100/110/115VAC)
(200/220/230VAC)
NOTE: Dotted sections are optional items and wirings.
TD (Transducer)
TD Junction Box
JB-32
Cable gland
Earthing lead
OW7/1.6S-3M
J7
TD cable
CW-836-3M
Figure 4.8 Inter-connections of CVS-841/CVS-851
4-6 93132682-03